Securitron Key Switch Wiring Diagram
See the connection diagram on the following page for how to wire the interface board to the WT1. 2 green square push button labeled push to exit swich mounted on single gang wallplate.
Valcom Valcom Digital 1 Zone Page Adapter V 9970 Digital Signal Processing Digital Adapter
Power supply may be ac or dc depending on the requirements of the strike.
Securitron key switch wiring diagram. Use the template diagram installation instructions included with the DM62 Magnalock assembly. Make sure the capacity of the. 1 each M62 electromagnetic lock.
Momentarily Turning the Key Changes the State of the Contacts. For Less Demanding Applications 2 Keys Included. 4 INSTALL 2 or 3 rubber washers on the 516-18 bolt.
Hotel Room Key Card Switch Wiring Diagram Premium Hotels Wiring Devices Catalogue Energy Saving Switch Card Holder For Hotels Company Andivi Building Automation. To order extra switches the Securitron part number for a momentary switch is MKS. For an alternate switch push on push off the part.
PIN DESCRIPTION WIRE COLOR WIRE CABLE ELYNX CABLE MISCELLANEOUS COMMENTS 1 Reader Power - Black Controller TS1 8 PIN -1 Ground 2 Reader Power Red Not Used 8 PIN. You can also view all Wiring Diagrams by leaving the fields blank and clicking the Search button. Push the box into the wall and secure in place using the two swing clamps.
Search Wiring Diagrams for HES and Securitron products. Connect wires to DK-12 wiring terminals see Section 3 for wiring instructions. 1 each 621RD EX DA exit pushbutton.
Request To Exit Maglock Wiring Diagram Cabinetdentaireertab Com In most cases that will be the keypad push to exit button motion sensor and kisi. The Securitron MKA is a single gang alternate action SPDT mortise keyswitch that turns a standard mortise cylinder into a full feature keyswitch. 1 each DK-26SS keypad.
7 Ampere Rated SPDT Switch. Momentary and alternate switches may be combined on the same unit. 2 INSERT the 516-18 bolt through the funnel bushing and strike plate see Diagram 10.
Finally the Securitron MagnaCare Lifetime Replacement Warranty is all-inclusive. 1224 Volt DC Bi-Color LED Tubular Style Keyswitches. Standard with 12 or 24VDC bi-color LED.
The DK-11s relay contacts will be interconnected in a dry state with the other switches. POWER AND ELECTRIC LOCK WIRING 1 2 3 4 5 6 JUMPER POWER SUPPLY ELECTRIC LOCK IF FAIL SECURE. The mounting diagram measurement and marking placement are critical.
5 INSTALL the roll pin bushings into the door see Diagram 11. A second switch ordered separately can be affixed to the unit so that turning the key left will depress one switch and turning it to the right will depress the other. 1 each BPS-24-1 power supply.
- WIRING INSTRUCTIONS fail safe strike with button and Keypad wired in series DC Power Supply Electromagnetic Lock or a Fail Safe Strike The strike is Polarity Insensitive Push Button NC Depressing the push button or activating the keypad would open the circuit stopping the flow of electricity and causing the magnet or strike to release. 1 each 653-05 key switch. Position the Magnalock centered between the doors.
1 each EEB2 redundant exit pushbutton. Mount DK-12 to box with either tamper resistant 6 screws recommended or 6 conventional screws. The mounting diagram is NOT a scaled template.
6 From the outside of the door gently TAP the sex bolt into place. A keyswitch sometimes called a lock switch is a switch that can be activated only by the use of a key. Backing bracket permits integration with any 1-14 32mm or 1-18 28mm mortise cylinder not included Additional switch position on backing bracket allows another switch to be activated by turning the key in the opposite direction.
MOV NOT REQUIRED IF SECURITRON MAGNALOCK IS USED 333 DC LOCK WITH DC POWER Select a power supply of the same voltage as the lock 12 or 24. The features to consideration during the installation procedure. Route wiring through one of the four knockouts in the back of the box.
DC LOCK - AC POWER WIRING NC1 C1 NO1 AC IN F DC IN OUT TRANSFORMER 12 OR 24 VAC DC FAIL SECURE OR FAIL SAFE LOCK MOV IF FAIL SECURE IF FAIL SAFE NOTE. 3 APPLY thread lock to the 516-18 bolt threads see Diagram 12. A simple electromagnetic locking system by Securitron might consist of.
Securitron provided a point-to-point wiring diagram to help speed the installation. Push to exit button wiring diagram. Use the fields below to narrow down your search.
The same lock the wire from terminal 1 to terminal 5 is often omitted as the DK-11s output relay may need to be in series or parallel with the other devices contacts. 1 each XMS exit sensor. The MKA supports electric lock control alarm panel arming reset and override when paired with any mortise cylinder 1-18.
5 Amp rated plunger switch. If something is wrong with a Securitron product you are installing they will replace it.